INFINITIES pLUS

FACIAL XMI840

RADIO WAVE LIFT

FACE THERAPY

Physical Standby therapy

Frequency adjustment Energy regulation Refrigeration

INSTRUMENT SAFETY

You must fill up the water before turning on the machine, otherwise the tr-eatment gun will be burned. When adding water, the vent will be opened and the water will be added from the filling hole.Water coming out of the vent hole means full water.

Machinery safety

This equipment is a movable equipment, before the product is operated a-nd used, the movable casters are set to the locked state. Unless otherwise specified, the equipment must not be operated with the-chassis open. When installing/unplugging all accessory plugs of the instrument, be sure to tighten the screw lock on the plug clockwise/counterclockwise The nee-dle is loosened.

TREATMENT INSTRUCTIONS

Before surgery 1. Consultation: communicate well with customers before treatment, what k-ind of treatment they have received, what are their reactions during treatme- nt,Have a history of allergies to ensure that the treatment can achieve the b-est results and the psychological needs of customers. 2. Identify the skin problems of customers, the number and depth of wrinkle-s, the thickness of pores, whether there are red blood streaks, and what are they What type of skin, what type of spots (deep, superficial, flaky, punctate) , and whether the spots are congenital or posterior God, is it still spreading, is the color continuing to deepen? 3. Cold gel: clean the treatment area, apply cold gel evenly, the thickness is 1- mm, nose and forehead Thicken the area (for hair removal projects, the hair must be shaved after cleaning the treatment area, 4. Power on operation: remove the bald head and place it below the body, tu-rn on the emergency power on, and use the key to power on repeatedly 2-3 times,To ensure the normal operation of the machine, touch the bald head to see if it is cool, first do a sensitivity test on your arm or hand. 5. Technical parameters: Before doing it, it is necessary to test sensitivity for customers. When adjusting energy parameters, in principle, it must be adju-sted from low to high(It is better to adjust no more than 2 energy points each-time), and at the sa-me time according to the color of the customer’ skin Small energy parameters, lighter colors can choose larger energy parameters) Consult and observe customers’feelings and reactions while doing Yes, if the customer feels a slight thorn or heat

Intraoperative

1. Take pictures and archive before and after surgery for comparison. 2. Clean the skin of the treatment area. During the treatment, please close y- our eyes or put on a protective eye mask for the customer.Spread the cold g-el evenly. 3. Choose the corresponding energy parameters according to different skin c- olors, skin thickness and pigment depth. 4. Test allergy in areas with mild symptoms or fair skin. 5. During the treatment, the head should not be emptied, and it must be in f-ull contact with the skin, but not heavy, and keep the bald head perpendicul-ar to the skin surface. Lift the skin to prevent light leakage, and find the corr-ect fit angle when treating the nose, cheekbones, and forehead. In operation, Take the face as an example. From bottom to top, from outside to inside, eac-h spot presses one-third of the other spot, evenly arranged Column, after ev-ery 4 or 5 light spots, stop and carefully observe the skin changes. Repeat for the more severe symptoms. treatment. 6. The treatment should always touch whether the bald head is still cold. If t-he bald head is hot, stop the operation immediately and lower the bald head-below At the body, let the refrigeration system fully circulate. Do not stick th-e skin for a long time during the treatment to prevent the bald head from be-ing too cold Hurt the skin.

Postoperative

1. Apply light energy conditioning cream after treatment to make the treatm-ent e ect better and more obvious, and promote recovery. Cold spray can be-implemented to reduce,Reduce customer symptoms. 2. After applying pure natural (plant-based) care products after treatment, us-e sunscreen (SPF20) or higher. 3. After finishing, observe the customer for half an hour before letting him lea-ve.

OPERATING INSTRUCT

1. Make sure that the client is lying relaxed on the beauty bed and wearing pr-otective goggles. 2. Clean the skin, clean the makeup residue and sunscreen on the skin. 3. Record the current number of pulses to calculate the accumulated energy. 4. Select the appropriate parameters, set the parameters and keep them. 5. Inspect the gun body to ensure that the gun body is in freezing state. 6. Put the handle perpendicular to the skin so that it is in full contact with the-skin. 7. Random skin tests are required to observe skin reactions after hair removal.

CONTRAINDICATIONS

The following people are not suitable for using this instrument for nursing: 1. Pregnant women, hypertension, heart disease, diabetes 2. It is forbidden for people who are allergic to light 3. People with open wounds 4. Do not do during menstrual.

MAINTENANCE / TROUBLESHOOTIN

Maintenance 1.Keep the instrument clean at all times. Clean the instrument after each us-e and put a dust-proof cloth cover on the instrument housing. The surface of the instrument can be wiped with a soft cloth. 2. The instrument should be operated by trained personnel. After the instru-ment is started, it is not allowed to leave without authorization. Full-time pe-rsonnel regularly check the host and Attachment to keep it in good condition. 3.Avoid harmful gases and corrosive liquids from flowing into the instrumen-t, and water in the main unit strictly to avoid leakage caused by short circuit. 4.The use environment of the whole machine should be a dry and ventilated-place. 5.The instrument is delicately bumped, and the inside of the instrument is a-precision electronic circuit, please do not open it without authorization.